metene td-4116 manual

Metene TD-4116 Manual⁚ Key Features

The Metene TD-4116 offers four testing modes⁚ QC (control), AC (before meal), PC (after meal), and Gen (general). It requires only 0.7µl of blood and provides results in 7 seconds.

Utilizing advanced biosensor technology, the TD-4116 delivers accurate and reliable blood glucose readings. A control solution is included for verification.

The device needs a minimal 0.7µl blood sample, obtained via fingertip or alternative sites. Results are displayed within 7 seconds of testing.

Testing Modes and Features

The Metene TD-4116 boasts versatile testing capabilities, catering to diverse user needs and schedules. It offers four distinct testing modes⁚ General (Gen) for anytime readings, Before Meal (AC) for pre-meal glucose checks, After Meal (PC) for post-meal monitoring, and Quality Control (QC) for verifying meter and strip functionality. This feature allows for comprehensive blood glucose tracking throughout the day, providing a holistic picture of glucose levels. The system’s ease of use is enhanced by its code-free design, eliminating the need for cumbersome coding procedures before each test. This streamlined approach minimizes testing time and enhances convenience, making it ideal for frequent monitoring.

Accuracy and Reliability

The Metene TD-4116 prioritizes precision and dependability in blood glucose measurement. Employing cutting-edge biosensor technology, the device ensures accurate readings, crucial for effective diabetes management. The system’s reliability is further bolstered by the inclusion of a control solution, allowing users to regularly verify the meter’s performance and the integrity of the test strips. This quality control measure minimizes the risk of inaccurate results stemming from malfunctioning equipment or degraded test strips. The combination of advanced technology and built-in quality checks instills confidence in the accuracy of the readings, empowering users to make informed decisions regarding their health and treatment plan. Regular use of the control solution is recommended to maintain optimal accuracy and reliability.

Blood Sample Requirements and Testing Time

The Metene TD-4116 boasts an impressively efficient testing process, minimizing discomfort and maximizing speed. A remarkably small blood sample volume of just 0.7µl is sufficient for accurate testing, reducing the pain and inconvenience associated with pricking the finger. This small sample size is achieved through the use of advanced technology in the test strips. The device provides rapid results, delivering blood glucose readings within a mere 7 seconds of sample application. This speed is invaluable for individuals needing frequent monitoring or quick feedback on their glucose levels. This combination of minimal blood requirement and rapid result delivery makes the TD-4116 a user-friendly and convenient option for managing diabetes effectively and efficiently. The quick turnaround time allows for immediate adjustments to treatment plans as needed.

Metene TD-4116 Manual⁚ Operational Guide

Insert the test strip, apply a blood sample, and wait for the 7-second reading. The display will show your blood glucose level.

Step-by-Step Testing Procedure

Turn on the Metene TD-4116 meter. 2. Insert a new test strip into the meter, ensuring the contact bar is fully inserted. 3. Using a sterile lancet, obtain a blood sample from your fingertip or an alternative site (following the instructions for alternative site testing). 4. Discard the first drop of blood. 5. Gently touch the blood sample to the test strip’s sample area. 6. Ensure sufficient blood is absorbed; wait for the result. 7. The meter will display your blood glucose level in mg/dL or mmol/L, along with the date and time. 8. Record the result in your logbook or using the data storage feature. 9. Safely dispose of the used lancet and test strip. 10. Turn off the meter after use.

Data Storage and Retrieval

The Metene TD-4116 boasts a memory capacity of 450 blood glucose readings, each timestamped with the date and time of testing. To access stored data, power off the meter. Navigate through the stored results using the meter’s buttons; the display will show the glucose level, along with the date and time of the test. The meter also calculates 14, 21, 28, 60, and 90-day averages of your blood glucose levels, providing a comprehensive overview of your blood sugar trends. For detailed analysis and data transfer, connect the meter (using a separately purchased USB cable) to a computer running the Metene healthcare software. This allows for a more in-depth review of your results and facilitates sharing with your healthcare provider.

Alternative Site Testing (AST)

While fingertip testing is generally preferred, the Metene TD-4116 allows for Alternative Site Testing (AST) from the palm, forearm, or upper arm. However, important limitations exist. AST results may not accurately reflect rapid changes in blood glucose levels caused by meals, exercise, or medication, therefore fingertip testing is strongly recommended during these times. AST should not be used for calibrating Continuous Glucose Monitors (CGMs) or for insulin dose calculations. Only use AST under steady-state blood glucose conditions. Consult your healthcare professional before using AST to ensure it’s appropriate for your individual needs and to understand potential inaccuracies compared to fingertip testing. Always follow the lancing device instructions for safe and proper sample collection from alternative sites.

Metene TD-4116 Manual⁚ Advanced Features

Transfer data to a PC using a USB cable (sold separately) and compatible healthcare software for detailed result analysis and tracking;

The TD-4116 includes a control solution to verify meter and strip functionality, ensuring accurate glucose readings.

The meter uses a single AAA battery. Low battery warnings appear on the screen to alert you to replace the battery.

Connecting to a Computer and Software

Enhance your diabetes management with the Metene TD-4116’s data transfer capabilities. Connect the meter to your personal computer using a USB cable (purchased separately) to seamlessly transfer your test results. This feature is facilitated by Metene’s dedicated healthcare software system, currently available for Windows operating systems. The software provides a comprehensive platform for reviewing your blood glucose readings, tracking trends over time, and generating insightful reports. This allows for a more detailed analysis of your blood sugar levels, empowering you and your healthcare provider to make informed decisions regarding your diabetes management plan. Remember that the meter cannot perform tests while connected to the PC. Consult local customer service or your place of purchase for assistance obtaining the necessary USB cable and software.

Control Solution Testing

Regularly verify the accuracy of your Metene TD-4116 glucose meter and test strips using the provided control solution. This solution contains a known glucose concentration, allowing you to check for proper functionality. To perform a control test, follow the instructions in your manual, ensuring you use a fresh control solution and a new test strip. Compare the meter reading to the expected range specified on the control solution bottle. If the result falls outside the acceptable range, it indicates a potential problem with either the meter or the test strips. Do not use the meter or strips if the results are inaccurate. Contact Metene customer service or your point of purchase for assistance. Remember, sharing lancing devices and lancets increases the risk of infection; use only personal supplies. Accurate control testing is essential for reliable blood glucose monitoring.

Battery Replacement and Low Battery Indicators

The Metene TD-4116 uses a single 1.5V AAA alkaline battery. The meter displays low battery warnings when power is low; these messages alert you to the need for a battery change. Before replacing the battery, ensure the meter is switched off. Open the battery compartment, carefully remove the old battery, and insert a new 1.5V AAA alkaline battery, ensuring correct polarity (+ and -). Close the battery compartment securely. After replacing the battery, you may need to re-set the time and date on the meter. Always use a fresh, high-quality battery to ensure accurate and reliable readings. A weak battery can affect the meter’s performance and lead to inaccurate glucose measurements. Discard used batteries properly according to local regulations. Regular battery checks are recommended to avoid unexpected interruptions in glucose monitoring.

Metene TD-4116 Manual⁚ Maintenance and Troubleshooting

Clean the meter with a soft, damp cloth. Avoid harsh chemicals. Disinfect with a recommended wipe, up to 10950 cycles.

Consult the manual for solutions to common problems, including error messages and low battery indicators.

The meter displays warnings for high/low glucose levels and other issues. Seek medical advice if necessary.

Cleaning and Disinfection

To maintain the hygiene and accuracy of your Metene TD-4116 blood glucose meter, regular cleaning and disinfection are crucial. Before each use, wash your hands thoroughly with soap and water to prevent contamination. After testing, gently wipe the meter’s surface with a soft, slightly damp cloth. Avoid using harsh chemicals, abrasive cleaners, or excessive moisture, as these can damage the device. For disinfection, use a recommended disinfecting wipe or towelette. The manufacturer states this device is validated for up to 10,950 cleaning and disinfection cycles (approximately 10 cycles daily for three years); It’s important to replace the meter after reaching this limit or the end of its warranty period, whichever comes first. Inspect the meter regularly for any signs of damage or deterioration. If you notice any cracks, discoloration, or other abnormalities, discontinue use and contact customer service for a replacement. Proper maintenance ensures the longevity and reliable performance of your Metene TD-4116.

Troubleshooting Common Issues

If your Metene TD-4116 displays an error message or provides unexpected results, consult this troubleshooting guide. “Low Battery” indicates the need for battery replacement (refer to the manual for instructions). Inaccurate readings might result from insufficient blood sample volume, improper test strip insertion (ensure the blue side faces up and the contact bar is fully inserted), or expired/damaged test strips. Check the expiration dates on your strips and ensure proper storage. If the meter displays “HIGH” or “LOW,” these indicate extremely high or low glucose levels, respectively, requiring immediate medical attention. If you experience persistent problems, verify you’re using only Metene TD-4116 test strips, as using incompatible strips leads to inaccurate results. For issues not resolved by these steps, contact Metene customer service or your healthcare provider for further assistance. Remember to always refer to the detailed instructions in your user manual for comprehensive troubleshooting.

Warnings and Error Messages

The Metene TD-4116 displays specific error messages to alert users to potential problems. A “Low” reading (below 20 mg/dL or 1 mmol/L) indicates hypoglycemia, requiring immediate medical attention. Conversely, a “High” reading (240 mg/dL or 13.3 mmol/L or above) suggests hyperglycemia and the possibility of ketoacidosis, especially in Type 1 diabetics; seek medical advice immediately. Other error messages may indicate issues with the test strip, such as improper insertion or expiration. Always ensure the test strip’s blue side is facing upwards and that the contact bar is fully inserted into the meter. If error messages persist despite following these steps, check the test strip expiration date, and examine the test strip and meter for any signs of damage or contamination. If problems continue, contact Metene customer support or your healthcare provider for assistance and consider replacing the meter or test strips.